Search
Close this search box.

VPL-A1002C-CJ14AA KINETIX; PERMANENT MAGNET ROTARY MOTOR, Servo Motor | Allen Bradley

Type number: VPL-A1002C-CJ14AA, Part No.: VPLA1002CCJ14AA, from manufacturer: Allen Bradley, Catagory: Kinetix VP Servo Motors Drives & Motors, VPL Low Inertia Motors

della101@163.com

Products Categories
Product Description
Module No. VPL-A1002C-CJ14AA
Product name 100mm Bolt Circle Frame Size, 2 (Two) Magnet Stacks, 2500 RPM Rated Speed, Single-turn …
Product description VPL-A1002C-CJ14AA KINETIX; PERMANENT MAGNET ROTARY MOTOR, Servo Motor | Allen Bradley
Part number VPLA1002CCJ14AA
Allen Bradley recommendation product VPL-A1002C-CK12AA VPL Low Inertia Motor | Allen Bradley
Voltage 230 VAC, 240 VAC, 480 VAC
Manufacturer Allen Bradley
Country of origin United States
Warranty 1-2 year
Shipping Method 1.Ship worldwide, usually 5-7 days.
2. We use DHL, FedEx, UPS,TNT
Remark If you need a specific firmware or series relating to VPL-A1002C-CJ14AA, please call or email us, we probably have it in our large inventory.
Product Catalogue

VPL-A1002C-CJ14AA KINETIX; PERMANENT MAGNET ROTARY MOTOR, Servo Motor | Allen Bradley

Performance Level(PL)and Safety Integrity Level (SIL)

For safety-related control systems,Performance Level (PL),according to EN ISO 13849-1,and SIL levels,according to IEC EN 61508 and

EN 62061,include a rating of the system’s ability to perform its safety functions.All ofthe safety related components of the control system must be included in a risk assessment and the determination of the achieved levels.

Refer to the EN ISO 13849-1,IEC EN 61508,and EN 62061 standards for complete information on the requirements for PLand SIL determination.

 

Safety-related Parameters

A motor that is equipped with a Hiperface DSL functional safety-rated feedback sensor is designed to maintain the functional safety rating of the feedback sensor attached.The safery parameters of the feedback sensors are as follows.

 

Attribute MotorCat.No.
VPL-xaxxxx-Wx1xAx VPL-xxxXxx-Qx1xAx
Safety Integrity Level(SIL) SIL2(IEC61508),SIL CL2 (EN 62061)
Probability of a Dangerous Failure per Hour (PFH) 4.0E-081/h 3.80 E-081/h
Safety (ategony (AL3(ENISQ 13849
Performance level (PL) PLd (ENISO 13849)

 

 

Motor Installation

Motor installation must comply with all local regulations and use ofequipment and installation practices that promote safety and electromagnetic compatibility:

  • Allmotorsincludc a mounting pilot for aligning the motor on a machinc
  • Preferred fasteners arestainless steel.
Related Products
Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)